Friedrich Error Code Search
Error code search offers information on the cause of the malfunction and the status of your air conditioner by entering the error code.
Disclaimer:
- This page provides a simple explanation concerning content relating to error codes and their possible causes. Please note that the content may slightly differ depending on the model.
2. It is always advised that you consult with an HVAC repair professional before attempting to provide any repairs yourself.
3. Precision Air assumes no responsibility for any accidents or troubles caused in the disassembly or repair of equipment performed according to the information on this page.
Caution:
If molded case circuit breakers or earth leakage circuit breakers have tripped, do not reset the breaker immediately without first checking for any problems with the insulation of equipment.
Resetting breakers without a check of insulation may cause damage to equipment.
Friedrich Air Conditioning Codes:
Alpha-Numerical AC Error Codes
Code: E1
High pressure system protection
Code: E2
Anti freezing protection
Code: F0
Refrigerant defects
Code: E4
High discharge temperature protection of compressor
Code: E5
Overcurrent Protection
Code: E6
Communication malfunction
Code: E8
High Temperature Resistant Protection
Code: EE
EEPROM Malfunction
Code: EU
Frequency reduction due to high temperature of module
Code: C5
Jumper cap malfunction protection
Code: DC
Bus bar PL voltage is too low
Code: F1
Indoor ambient temperature sensor is open / small circuit
Code: F2
Indoor evaporator temperature sensor is open / small circulated
Code: F3
Outdoor ambient temperature sensor is open / small circulated
Code: F4
Outdoor condenser temperature sensor is open / small circulated
Code: F5
Outdoor discharge temperature sensor is open / small circulated
Code: F6
Decrease frequency due to overload
Code: F8
Frequency decrease due to overcrack
Code: F9
Reduction in frequency of due to high air discharge
Code: FH
Decrease frequency due to anti freezing
Code: H0
Frequency of decreases due to high temperature resistor during heating operation
Code: H1
Defrosting
Code: H2
Static surrender protection
Code: H3
Overload protection for compressor
Code: H4
System is abnormal
Code: H5
IPM Security
Code: H6
Internal motor (fan motor) does not operate
Code: H7
Desynchronizing of Compressor
Code: HC
PFC Security
Code: L3
Outdoor DC Fan Motor Malfunction
Code: L9
Power Protection
Code: LC
Failure startup
Code: LP
Does not match indoor unit and outdoor unit
Code: P0
Compressor minimum frequency in test state
Code: P1
Compressor rated frequency at test stage
Code: P2
Compressor maximum frequency in test state
Code: P3
Compressor intermediate frequency in test state
Code: P5
Overload protection of phase current for compressor
Code: P7
Module temperature sensor circuit malfunction
Code: P8
Module High Temperature Protection
Code: PH
Voltage too high for DC bus bar
Code: U1
Malfunction of phase current detection circuit for compressor
Code: U3
Malfunction of voltage dropping for DC bus bar
Code: U5
Malfunction current detection of complete units
Code: U7
Four-way valve is abnormal
Code: U9
Zero-crossing Outdoor Unit Malfunction
Numerical AC Error Codes
Error Code: 02
Extremely low voltage conditions exist 198V for 230V units and 239V for 265V units
FIX: Shutdown unit
Error Code: 03
Return air thermistor sensor open or short circuit
FIX: Set the return air sensor = 75 ° F
Error Code: 04
Indoor coil temperature sensor open or short circuit
FIX: Set ID coil temp = 40 ° F
Error Code: 05
Outdoor coil thermistor sensor open or short circuit
FIX: Set indoor coil temp = 20 ° F.
Error Code: 06
Outdoor coil temperature over 175 °F
FIX: Shut down unit for 5 minutes
Error Code: 07
Indoor coil temperature is below 30 ° F
FIX: Shut down unit for 5 minutes. The compressor remains closed until the indoor coil thermistor reaches 45 ° F.
Error Code: 08
Low load conditions
FIX: Contact technician
Error Code: 09
High load conditions
FIX: Contact technician
Error Code: 10
Room Freeze Protection Trigger
FIX: Keep unit running